Abstract

Experiments were carried out to ascertain multichannel discharge characteristics in a self-designed coaxial field-distortion gas switch filled with SF6-N2 or SF6-Ar gas mixtures of different mixing ratios. In these experiments, the pressure varied from 0.1 MPa to 0.2 MPa, the voltage pulse peak applied to the switch was in the range from 40 kV to 78 kV, and the pulse rise time was 11 ns. The static breakdown strength of the gas switch gap in the switch was also measured. The results show that in general the average number of discharge channels for SF6-Ar or SF6-N2 gas mixture which contains less SF6 is larger than that for gas mixture which contains more SF6, however, the average number of channels almost keeps constant as the gas mixing ratio varies when the pulse rise rate is high enough. The static breakdown strength of the gas switch gap decreases slightly as the content of argon or nitrogen increases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.