Abstract

We report on a compact and simple, broadband optical parametric chirped pulse amplifier system that amplifies femtosecond pulses directly from a titanium sapphire oscillator up to 2 TW power. Our system relies on a new technique - time shear - that improves the time overlap between the seed and pump pulses and, thus, improves the efficiency of the power amplification stage pumped with a ns laser. Parametric amplification was achieved in two stages: a multipass, noncollinear geometry preamplifier with a single beta-barium borate crystal, and a power booster stage incorporating three beta-barium borate crystals in the new time-shear design. Both stages were pumped with pulses from a commercial 10 Hz frequency doubled ns Nd:YAG laser. The system delivers 49 mJ pulses with a temporal width of 23 fs and its overall conversion efficiency after pulse compression is 10%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.