Abstract

The objective of this study was to assess the diagnostic value of magnetic resonance cholangiopancreatography (MRCP) at 0.5 T. The MRCP technique was performed in 28 patients with symptomatology referrable to the biliary system. A three-dimensional (3D) inversion recovery turbo-spin-echo (TSE) sequence was used to create 3D reconstructions of the bile ducts. Dilation of the biliary tree or pancreatic duct in 23 patients due to tumor, calculi, or strictures was depicted with excellent contrast resolution. The approximate level of obstruction and all calculi were accurately predicted by MRCP. In another 3 patients no cause was found for the biliary dilatation. In the last 2 cases no abnormalities were found by either MRCP or endoscopic retrograde cholangiopancreatography (ERCP). The MRCP technique at 0.5 T is an accurate method for the assessment of pathology of the biliary tree.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.