Abstract

To measure air excess ratio in exhaust gas, sensors which measure oxgen density in the gas by solid oxide electrolyte with gas diffusion layer are used. In this paper, the movement of oxygen in the gas diffusion layer by solid oxide electrolyte is simulated by Nelnst's equation oxide electrolyte and diffusion equation for gas diffusion layer. As a result, authors confirmed that the current value at the solid oxide electrolyte with the change of oxgen density distribution in gas diffusion layer is consistent with the experimental value, and is effected by the thickness of the diffusion layer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.