Abstract

Normal load and abnormal load conditions for valve actuators are discussed and load characteristics are illustrated for typical valves. Overload protection for short time duty rated motors is discussed when twice normal loads occur and when locked rotor occurs. The required performance of the overload device is outlined with emphasis on protection during locked rotor. The condition of locked rotor temperature rise is analyzed and tests conducted to compare with calculated values. Different types of overload protection devices are described and the limited protection provided by the internal temperature sensor under the conditions of locked rotor is pointed out. A systematic approach to external overload relay selection is illustrated

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.