Abstract

A freestanding submicron thin film specimen is designed and fabricated here to carry out a series of monotonic and fatigue testing. This freestanding beam was loaded by performing monotonic loading/unloading or closed-loop load controlled tension–tension fatigue experiments on it. Loading was applied using a piezoelectric actuator with 0.1 μm resolution connected to the test specimen. Loads were measured by connected a capacitor load cell with a resolution of less than 0.1 mN. The modulus, yield stress and maximum stress of tested submicron thin films at room temperature were found from monotonic loading/unloading tests. The results of 300 nm copper thin films fatigue experiments demonstrated a trend of decreasing cycles to failure with increasing loading amplitude and increasing mean stress.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.