Abstract

ABSTRACT J. Inst. Brew. 117(4), 639–646, 2011 In this work, different aspects of particles size distribution in filtered beer were investigated. The utilisation of commercial cellulase or protease formulations influenced significantly the stability of filtered beer. By using Photon Correlation Spectros-copy (PCS) untreated beer samples at 6 and 20°C showed good “chill” stability, while the samples treated with exogenous en-zymes showed a significant modification in the particles size distribution and reduced colloidal stability. The particles size distribution in the filtrate appeared to be related to the decrease of the cut-off size of the membrane and of the flux from the membrane. As reported, the largest particle size diameter flow-ing through the membrane decreased in each type of sample over the course of the filtration, due to the fouling of the filtering media. The results allowed confirmation that at the beginning of the filtration trials the main fouling cause was the decrease of the pores size within the membrane structure, more than cake formation over the membrane surface, although this second ef-fect prevailed after a certain time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.