Abstract
Error compensation in optical monitoring was demonstrated many years ago for narrow bandpass and edge filters. It is shown here that the compensation effects can apply to a broader range of more general coatings. This is illustrated with a very broadband antireflection coating design of 20 layers and a ramp design of 13 layers. The choice of monitoring wavelength and monitoring strategy are important, and suggestions are made concerning those choices. The results are derived from and demonstrated by computer simulations of the monitoring processes. The importance of monitoring directly on only one part and with one wavelength throughout the process in order to obtain the benefits of error compensation is emphasized.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.