AbstractEstimations of gas wall, liquid wall and interfacial friction factors for two‐phase horizontal co‐current pipe flow are discussed critically after being checked against reliable data obtained under a wide range of conditions. The use of equivalent diameters and the Blasius relation were shown to be valid for estimation of the gas wall friction. Prediction of liquid wall and interfacial friction factors proved to be more difficult but estimation improved if consideration was given to the effects of liquid holdup and interfacial liquid shape.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.