Abstract

In order to achieve larger spans of timber arch bridges, glulam massive timber sections must be spliced on-site by moment resisting and rotationally stiff joints. In this paper, a novel timber splice connection utilizing long threaded rods and grout-filled couplers is presented. Flexural characteristics of the splice joint were investigated by full-scale experimental tests and 3D finite element models. An analytical model is proposed for determining the moment capacity and the rotational stiffness of the splice connection. The experimentally measured efficiency of the splice connection with regard to moment capacity and rotational stiffness was 69% and 66%, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.