Abstract

The slanted-edge method specified in ISO Standard 12223, which experiences large errors in the camera modulation transfer function(MTF) due to tilt angle error in the knife-edge resulting in non-uniform sampling of the edge spread function. In order to resolve this problem, a modified slanted-edge method for camera MTF measurement is proposed. By applying a simple direct calculation of the Fourier transform of the derivative for the non-uniform sampling data, the camera super-sampled MTF results are obtained. Theoretical simulations for images with and without noise under different tilt angle errors are run using the proposed method. It is demonstrated that the MTF results are insensitive to tilt angle errors. To verify the accuracy of the proposed method, an experimental setup for camera MTF measurement is established. Measurement results show that the proposed method is superior to traditional methods, and improves the universality of the slanted knife-edge method for camera MTF measurement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.