Abstract

Both high-flow vascular access (VA) and dialysis-associated steal syndrome are serious complications requiring a flow reduction technique. We adopted the minimally invasive limited ligation endoluminal-assisted revision (MILLER) banding procedure with some modifications to control the high blood flow and steal syndrome during VA procedures and retrospectively assessed the outcome. Seven patients with high-flow access (access flow >1400 ml/min) and five patients with steal syndrome (with pain, coldness, or cyanosis) were treated using the MILLER banding method. Flow volume of the brachial artery was monitored using Doppler ultrasonography during the banding procedure. In patients with steal syndrome, the finger probe of a pulse oximeter was attached to a finger on the ipsilateral side, and the peripheral oxygen saturation (SpO2) was monitored. In the high-flow group, the mean access blood flow (Qa) decreased from 2043 ± 463 ml/min (mean ± SD) to 1248 ± 388 ml/min (p<0.001). In the steal syndrome group, the SpO2 value improved in all steal syndrome patients after banding. Symptoms were almost relieved in two steal syndrome patients. The Qa in the steal group decreased from 997 ± 867 to 548 ± 376 ml/min (p = 0.12). The secondary patency rates of the high-flow and steal groups at 6 months were 83.3% and 50%, respectively. The MILLER banding procedure with intraoperative access flow monitoring is effective to treat high-flow VA and steal syndrome.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.