Abstract

Existing interim spent nuclear fuel storage facility (SNFSF) at Ignalina nuclear power plant in Lithuania is fully loaded with CASTOR®RBMK-1500 and CONSTOR®RBMK-1500 storage casks. The planned lifetime of these casks is 50 years and the first loaded cask was moved to the SNFSF in 1999. The start of operation of disposal facility in Lithuania is foreseen later than the planned interim storage ends. So, the possibilities to extend the storage period over 50 years should be considered. Therefore, the casks decommissioning issues should be taken into account, as due to prolonged neutron irradiation casks materials could became activated.This paper presents modelling results of storage casks neutron activation during 300 year storage period. Modelling results show, that after 50 years of storage, side-wall and bottom of CASTOR®RBMK-1500 cask are activated above clearance criteria. However, for 100–300 year storage period all of the casks components could be free released.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.