Abstract
A numerical model of a proton exchange membrane fuel cell has been developed to predict the performance of a large active area fuel cell with the water cooling thermal management system. The model includes three submodels for water transport, electrochemical reaction, and heat transfer. By integrating those submodels, local electric resistance and overpotential depending on the water and temperature distribution can be predicted. In this study the effects of the inlet gas temperature and humidity on the fuel cell performance are explored, and the effect of the temperature distribution at different coolant temperatures is investigated. The results show that the changes in local electric resistance due to temperature distribution cause fuel cell power decrease. Therefore, the coolant temperature and flow rate should be controlled properly depending on the operating conditions in order to minimize the temperature distribution while maximizing the power output of the fuel cell.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.