Abstract

In this paper, the effect of radius variation of beam light on output efficacy of SFD Yttrium aluminium borate laser doped with Neodymium ion, which is simultaneously a non-linear and active laser crystal, is investigated in a double-pass cavity. This is done with a concave lens that concentrates (Reduction of optical radius within nonlinear material) as much optical laser as possible, resulting in increasing the laser efficiency, second harmonic and the population inversion difference. In this study, we first developed five discrete differential equations describing the interactions of 807 nm pump beam, 1060nm laser beam and 530nm second harmonic beam. Output efficiencies of laser and second harmonic beams at pumping power of Pp =20W and beam radius of 5μm have been presented. Meanwhile, in this paper, the first experiment for creating second harmonic in solid state lasers was fully described with a figure and its procedure was investigated and then the equations (second harmonic and laser and population inversion) were studied. Radius variation of beam light aims at increasing laser output efficacy and improving second harmonic and population inversion. The analytic methods which have been solved the discrete differential equations via Matlab.

Highlights

  • Having used non-linear optical materials like harmonic producers and optical parameters oscillators, we can develop the frequency area in accessible lasers well

  • NYAB solid-state laser is an active non-linear crystal which has been studied in recent years due to its ability in producing green light laser

  • High effective non-linear coefficient and high damage threshold provides the possibility of being polluted with high value of ND ion, possibility of making pumped laser with diode in green area via self doubler (SFD) NYAB crystal has been the most efficient self doubler laser

Read more

Summary

1- Introduction

Having used non-linear optical materials like harmonic producers and optical parameters oscillators, we can develop the frequency area in accessible lasers well. 4- Output Efficacy of Forward Second Harmonic Beam along Z-Direction for Beam Radius of rp = 5μm. Output efficacy of forward second harmonic beam along Z=5 mm for pumping power of Pp=20W and beam radius of rp=5mm is 0.634 %. Output efficacy of backward second harmonic beam along Z=5 mm for pumping power of Pp=20W and beam radius of rp=5mm is 0.6327 %. Output efficacy of forward laser beam along Z=5 mm for pumping power of Pp=20W and beam radius of rp=5mm is 34.1%.

10- Conclusion
Findings
12- References

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.