Abstract

The micrometer-scale tube that fills capsules with thermonuclear fuel in inertial confinement fusion experiments at the National Ignition Facility is also one of the implosion's main degradation sources. It seeds a perturbation that injects the ablator material into the center, radiating away some of the hot-spot energy. This paper discusses how the perturbation arises in experiments using high-density carbon ablators and how the ablator mix interacts once it enters the hot-spot. Both modeling and experiments show an in-flight areal-density perturbation and localized x-ray emission at stagnation from the fill-tube. Simulations suggest that the fill-tube is degrading an otherwise 1D implosion by ∼2×, but when other degradation sources are present, the yield reduction is closer to 20%. Characteristics of the fill-tube assembly, such as the through-hole size and the glue mass, alter the dynamics and magnitude of the degradation. These aspects point the way toward improvements in the design, some of which (smaller diameter fill-tube) have already shown improvements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.