Abstract

Soft-storey mechanism is characterized by a sudden reduction of lateral stiffness in one or more levels of a structure. Soft-storey is often observed in the ground level due to the absence of wall or cladding. With recent develop of energy dissipation systems, soft-storey mechanism can be corrected by addition of a damper-brace assembly. In particular, this paper investigates the effect of toggle-damper-brace systems on such situations. Governing equations including the magnification factor and lateral stiffness contributed by a toggle-damper-brace are formulated. It was found that a toggle-damper-brace system, if proportioned correctly, will significantly increase the travel in the damper and overall stiffness of structure can be enhanced. An illustrative example is presented using nonlinear time history analysis implemented on MATLAB.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.