Abstract

In permanent magnet (PM) synchronous machines, iron losses form a larger portion of the total losses than in induction machines. This is partly due to the elimination of significant rotor loss in PM machines and partly due to the nonsinusoidal flux density waveforms in the stator core of PM machines. Therefore, minimization of iron losses is of particular importance in PM motor design. This paper considers the minimizing of iron losses of PM synchronous machines through the proper design of magnets and slots, and through the choice of the number of poles. Both time-stepped finite element method (FEM) and the iron loss model from a previous study are utilized in this paper to draw the conclusions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.