Abstract
BackgroundThe concept of minimally invasive surgery (MIS) was introduced in total knee arthroplasty (TKA) in the late 1990s. The number of MIS TKAs has clearly decreased in recent years. An implant designed specifically for MIS TKA has been used all over the world, but there are no reports of long-term postoperative results. The purpose of this study was to characterize long-term clinical results with a minimum follow-up of 10 years.MethodsThis retrospective study included 109 consecutive patients with 143 NexGen CR-Flex prostheses, which are MIS tibial component prostheses designed specifically for MIS TKA. Twelve-year survival analysis was performed using Kaplan-Meier method. Revision surgery for any reason was the endpoint. Long-term clinical and radiographic results of 74 knees (55%) in 60 patients with more than 10 years of follow-up were analyzed.ResultsThe cumulative survival rate of the single-radius posterior-stabilized TKA of 74 knees was 94.7% (95% confidence interval, 90–99%) at 12 years after surgery. Seven knees (9%) required additional surgery during the 10-year follow-up because of periprosthetic infections. Mean postoperative Knee Society knee score and functional score were 91 and 74 points, respectively. There were no cases of prosthesis breakage, polyethylene wear, or aseptic loosening of the prosthesis.ConclusionThe prosthesis designed specifically for MIS TKA is associated with good survival and clinical results with a minimum follow-up of 10 years, even though MIS TKA has become less popular.Level of evidenceIII
Highlights
The concept of minimally invasive surgery (MIS) was introduced in total knee arthroplasty (TKA) in the late 1990s
The National Joint Registry (NJR) of England and Wales showed that 2.5% of TKAs were done via MIS in 2014, down from 3.8% in 2009 when MIS TKA reached its peak popularity [11]
The number of MIS TKA procedures in England and Wales recorded in the NJR clearly shows a decrease over recent years [12]
Summary
The concept of minimally invasive surgery (MIS) was introduced in total knee arthroplasty (TKA) in the late 1990s. The number of MIS TKAs has clearly decreased in recent years. An implant designed for MIS TKA has been used all over the world, but there are no reports of long-term postoperative results. The mid-term results reported so far have not shown a significant difference between MIS TKA and the standard approach [5,6,7,8,9,10]. The number of MIS TKA procedures in England and Wales recorded in the NJR clearly shows a decrease over recent years [12]. Searching for MIS TKA on PubMed shows that the number of publications has decreased sharply since 2012 (Fig. 1). An implant designed for MIS has been used all over the world, but there are no reports of long-term postoperative results
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.