Abstract
The authors report the safety and efficacy of using a percutaneous minimal-access insertion technique for distal shunt catheter placement in 100 cases. From June 2007 to March 2008, they attempted 100 minimal-access insertions of distal shunt catheters in 91 patients who required ventriculoperitoneal shunting. Using the minimal-access approach, they avoided utilizing laparoscopic assistance or a mini-laparotomy in 91% of the cases. There were no bowel injuries or misplaced distal catheters. Additional outcomes in terms of operative times, cases that required conversion to open or laparoscopically assisted implantation, and infection rates are presented. They conclude that intraperitoneal shunt catheter placement can be safely and effectively accomplished using a simplified percutaneous minimal-access insertion method that does not require direct laparoscopic visualization.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.