A study was carried out to determine arsenobetaine (AB) in brines from canned seafood products by coupling high-performance liquid chromatography (HPLC), microwave-assisted oxidation (MO), and hydride generation-atomic absorption spectrometry (HG-AAS). Conditions were established for cleanup of the brines prior to HPLC determination of AB. The analytical features of the method for AB determination in brines were as follows: the detection limit was 2.0 ng g-1 As (fresh mass), the mean relative standard deviation 3%, and the mean recovery percentage 99 ± 4%. The proposed procedure was used to analyze AB in brines from canned seafood purchased at local retail outlets. The ranges of total arsenic and AB expressed as As (both in μg g-1 of fresh mass) were as follows: total arsenic, 0.06−3.64; AB, 0.05−3.87. The percentage of total arsenic represented by AB in brines varied from 48 to 110%. The migration of AB from muscle tissue to the brine does not rule out the possible presence in brines of other toxic spe...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.