Abstract

In this study, the uniaxial tension-tension fatigue behavior of fully nanotwinned magnetron sputtered Cu-6wt%Al, Cu-2wt%Al, and Cu-10 wt%Ni is presented. These alloys have average twin thicknesses ranging from 4 to 8 nm, average grain widths from 90 to 180 nm, and tensile strengths from 1 to 1.5 GPa. In the high cycle regime (103 to 107 cycles), the nanotwinned alloys exhibit fatigue strengths ranging from 210 to 370 MPa, which is higher than previously observed in nanotwinned Cu (fatigue strengths between 80 and 200 MPa). Fatigue strengths are normalized by tensile strength for Cu alloys with different microstructures to study the correlation between tensile and fatigue properties. Post-mortem analysis of the materials reveals a newly observed deformation mechanism, where localized detwinning leads to intergranular fracture between columnar grains. Overall, materials displaying detwinning as a deformation mechanism show lower normalized fatigue strengths in comparison to materials that deform with slip band like behavior.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.