Abstract

In this paper we report a perfusion culture microchamber array chip with a serial dilution microfluidic network for analyzing drug dose response over a concentration range spanning 6 orders of magnitude, which is required for practical drug discovery applications. The microchamber array chip was equipped with a pressure-driven interface, in which medium and drug solution were added with a micropipet and delivered into the microfluidic network by pneumatic pressure. We demonstrated that the microchamber array chip could be used to estimate the 50% growth inhibitory concentration using the model anticancer drug paclitaxel and the model cancer cell line HeLa. The results obtained by using the microchamber array chip were consistent with those obtained by a conventional assay using microplates. The microchamber array chip, with its simple interface and well-designed microfluidic network, has potential as an efficient platform for high-throughput dose response assays in drug discovery applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.