Abstract

We have identified three process variables which determine the sphericity of polymer shells made by dual orifice microencapsulation. 1) The density mismatch between the outer aqueous solution and the polymer oil phase must be minimized. We have minimized this density mismatch by adjusting the water bath temperature. 2) The stir rate has an effect, with a minimum non-sphericity located near 50–70 rpm stir rate. 3) The outer aqueous solution must have enough total oil solvent (fluorobenzene in the drops) to be beyond the aqueous saturation level (1.5 g/ℓ) at the beginning of the solvent extraction. Using the optimal conditions for a 1000 μm o.d. shell, we produce a minimum variation in the radius of a given shell, in the neighborhood of 0.4 μm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.