Abstract

Abstract The aim of this research was to evaluate the microbiological indoor air contamination level in chosen facilities of the primary health-care for adults and children. The total numbers of mesophilic bacteria, staphylococci, coli-group bacteria and moulds in both surgery rooms and patients’ waiting rooms were determined. Air samples were collected with a MAS 100 impactor and the concentration of microorganisms was estimated by a culture method. The microbiological air contamination level was diverse: the number of mesophilic bacteria ranged from 320 to 560 CFU/m3, number of staphylococci - 10-305 CFU/m3, coli group bacteria - 0-15 CFU/m3 and moulds - 15-35 CFU/m3. The bacteriological contamination level of the air in examined community health centers was higher than described in the literature for hospitals and exceeded the acceptable values proposed for the surgery objects.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.