Abstract

We report the performance of a commercial recuperated micro gas turbine on biomass producer gas and mixtures of biomass producer gas with natural gas. The biomass producer gas, obtained by gasification at 850 °C with air at atmospheric pressure, contains about 7% H2, 17% CO, 15% CO2, 4% CH4, 2% other hydrocarbons, 2% H2O, and a balance of N2 and Ar from air. It has a net heating value of about 6 MJ/(N m3). The micro gas turbine delivers full power (30 kWe) on gas mixtures with a net heating value of at least 15 MJ/(N m3). For gas of lower heating value, the maximum fuel gas flow allowed by the fuel control unit limits the attainable power. At reduced power, the lower limit for stable operation is a net heating value of about 8 MJ/(N m3). The gross efficiency of the micro gas turbine depends on the output power but not on the gas heating value, within our estimated measurement accuracy of about 2%. Above 70% of full power, NO emission is 5 times lower than that allowed by Dutch or German legislation, and C...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.