Abstract
The causes of and conditions for the manifestation of distortions in calculations conducted by the method of auxiliary temperatures are exposed. It is indicated that the distortions are maximum beneath the edges of structures, where the design frost depth may be on the low side by a factor of two and more. A computational method, which is free of exposed drawbacks and which indicates agreement with the results of numerical modeling is developed, proceeding from analytical solution of the problem of the motion of the phase interface in quasi-stationary approximation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.