This paper presents the impact of guard grill on aerodynamic integral characteristic, the spectrum of sound pressure level and total sound power level at four characteristic operating points of axial fans with standard guard grill, with optimized guard grill and without guard grill. The study of guard grill’s impact was conducted with measurements at integral level and local outflow velocity field of the axial fan without guard grill. The measurement results of the local outflow velocity field of the axial fan without guard grill at optimal operating point were used to model the optimized guard grill contour. The guard grill of axial fan has a significant impact on aerodynamic integral characteristic at free flow and mostly used operating region. The influence of guard grill is also characteristically reflected in the spectrum of sound pressure level via vortex shedding frequency and consequently at total sound power level of compared axial fans.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.