Abstract
Analytical method has been developed and validated to determine free or leachable furfural concentration in wood-based panels. Particleboards obtained from birch wood and suberinic acids binder were chosen as a reference material. Two methods and two solvents were tested. Acetone extracts of the samples were analyzed with gas chromatography (GC) flame ionization detector system. Water extracts were analyzed with high-performance liquid chromatography-ultraviolet spectroscopy (HPLC-UV) system. After the GC data in acetone extracts furfural concentration was below method limit of detection. HPLC-UV data showed that in water extracts furfural concentration was possible to determine. It was concluded that HPLC-UV is suitable and fast method for furfural determination in wood-based panels water extracts.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.