Abstract

The effective thermal diffusivity and conductivity of pebble bed in the high temperature gas-cooled reactor (HTGR) are two vital parameters to determine the operating temperature and power in varisized reactors with the restriction of inherent safety. A high-temperature heat transfer test facility and its inverse method for processing experimental data are presented in this work. The effective thermal diffusivity as well as conductivity of pebble bed will be measured at temperature up to 1600 °C in the under-construction facility with the full-scale in radius. The inverse method gives a global optimal relationship between thermal diffusivity and temperature through those thermocouple values in the pebble bed facility, and the conductivity is obtained by conversion from diffusivity. Furthermore, the robustness and uncertainty analyses are also set forth here to illustrate the validity of the algorithm and the corresponding experiment. A brief experimental result of preliminary low-temperature test is also presented in this work.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.