Abstract

ObjectiveThis is a description of complications following prolapse surgery with the use of alloplastic materials, the management and outcome. Study design54 women have been referred to Mainz, urogynecology referral center due to complications following mesh-augmented prolapse surgery. ResultsThe complaints who lead to the admission are expressed by the new terminology and standardized classification for complications arising directly from the insertion of prostheses and grafts in female pelvic floor surgery [1]. Pain (66.7%), mesh erosion (55.6%) and vaginal discharge (48.1%) were the most frequent complaints. Revision was performed after a median time of 27.2 months post mesh implantation. Nine patients underwent limited excision of the mesh, 49 had a vaginal revision with wide mesh removal and 10 had a laparotomy with wide mesh removal. After 3 months 48 patients had a follow-up, 25 could have been relieved from their complaints. ConclusionAlthough the incidence is low, complications after prolapse repair with mesh use are difficult to prevent, affect quality of life and often require a new surgical intervention, which should be performed by an experienced and competent surgeon.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.