Abstract

Digital implant planning, utilizing the convergence of digital surface scanners, cone beam computer tomography (CBCT) scans, and advanced planning software, has transformed dental implantology. The merging of these data sets through triangulation of landmarks provides a detailed digital model of the jaws, facilitating precise implant positioning in edentulous areas. A critical step in this digital workflow is the accurate merging of DICOM files with STL/PLY/OBJ files, which underpins the design and fabrication of surgical templates for accurate implant placement. Errors in this phase can lead to implant mispositioning or damage to adjacent structures. Particularly in partial edentulism, the merging is based on the occlusal topography of the remaining teeth but scattering in the CBCT data-caused by interactions of radiation with radiodense materials-can complicate this process or even render it impossible. The manuscript presents a technique utilizing radiopaque markers to overcome scattering effects, ensuring accurate dataset superimposition in the mandible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.