Abstract
Membrane currents of identified, isolated corticotropes and gonadotropes from mammalian anterior pituitary gland have been evaluated. Pituitary gonadotropes and corticotropes were isolated enzymatically and stained in the living state using biotinylated gonadotropin-releasing hormone (Bio-GnRH) or biotinylated corticotropin-releasing hormone (Bio-CRF) followed by avidin fluorescein. Electrophysiological recordings were made with patch-clamp electrodes in the whole-cell clamp configuration. Tetrodotoxin (TTX)-sensitive sodium currents were larger in corticotropes than in gonadotropes. Corticotropes showed two components of calcium currents, a transient low-threshold component and a longer lasting high-threshold component. Small TTX-resistant inward currents were present also in gonadotropes, and both cell types had transient and steady potassium currents.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.