Abstract

The water vapour permeability is a material property used in calculations of the hygrothermal performance of buildings. The standard test method (the ‘cup test’), little changed for decades and based on measuring weight changes, has been shown repeatedly in round-robin comparisons to have poor accuracy and little consistency between laboratories. Here we describe a new approach in which the primary measurement is of the humidity difference across the test sample, which is monitored continuously using sensors that are remotely readable. The box-in-box (BiB) apparatus described is smaller and simpler than that of the standard cup test. The BiB test is of shorter duration and is carried out without disturbance to the sample. New results on calcium silicate sheet, brick ceramic and autoclaved aerated concrete are compared with published vapour permeability values obtained by the standard test (considered to be of lower accuracy).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.