Abstract
The investigation of a pilot operated proportional pressure relief valve is described in this article. Different measurements are performed with a hydraulic test bench under laboratory conditions. A VT-VSPA1-1 amplifier module is used to control the current of the valve’s solenoid. The characteristics of the valve are determined as a function of the pressure – command value of the amplifier – volume flow rate. The results of the measurements can provide input data for the refinement of the mathematical model of the unit, which will be set up in the future.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.