Abstract
Uranium, radium concentration and radon exhalation rate in twenty one building material samples collected from markets of Iraq were measured using the sealed-can technique based on the CR-39 SSNTDS. The values of effective radium content were found to vary from (0.037 to 4.986) Bq/kg with a mean value of 0.745Bq/kg. The values of mass exhalation rates of radon vary from (0.688 ×10−8 to46.910×10−8) Bq/kg.day with a mean value 7.012×10−8Bq/kg.day, while the surface exhalation rates of radon vary from (0.344×10−6to23.472×10−6)Bq/m2.day with a mean value of 3.508×10−6Bq/m2.day. Uranium content in these samples has been found, it is varying from 0.074 to 5.055 ppm with a mean value of 0.755ppm. The mean values of radon exhalation rate, radium content and uranium concentration in building material samples of study area were found well below the values of 57.600 mBq/m2.h , 370 Bq/kg and 3ppm, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.