A small spherical probe is used in conjunction with a network analyzer to determine the impedance of the probe-plasma system over a wide frequency range. Impedance curves are in good agreement with accepted circuit models with plasma-sheath and electron plasma frequency resonances easily identifiable. Clear transitions between capacitive and inductive modes as predicted by the model are identified. Sheath thickness and absolute electron density are determined from the location of these transitions. The absolute electron density indicated by the location of the impedance resonance is compared to measurements using the plasma oscillation method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.