Abstract
This paper presents theoretical and experimental relationships between radiated electromagnetic noises and common-mode and normal-mode currents, paying attention to an induction motor drive system fed by a voltage-source pulsewidth modulation (PWM) inverter. A method of reducing both currents is proposed, based on an equivalent model, taking into account parasitic stray capacitors inside an induction motor. Electromagnetic interference (EMI) radiated by a 3.7-kW induction motor drive system is actually measured, complying with the VDE 0871 Class A [3 m]. Experimental results verify that the combination of the already proposed common-mode transformer (CMT) and the normal-mode filters (NMFs) being proposed in this paper is a practically viable and effective way to reduce EMI resulting from both common-mode and normal-mode currents.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.