Abstract
We have verified the capability of a CR-39 track detector for isotope identification using iron beam from the heavy-ion accelerator of HIMAC at NIRS. The same CR-39 stack was independently exposed to 56Fe and 55Fe ions with an energy of 460 MeV/nucleon. Mass resolutions for 56Fe and 55Fe ions were determined to be 0.28±0.12 amu and 0.28±0.11 amu in rms, respectively. A detailed analysis of the sources of the mass dispersion in the present mass identification experiment showed that significant errors were caused in the measurements of the surface position and the thickness of CR-39 sheets. By eliminating these errors as much as possible, the mass resolution is expected to be improved to ∼0.20 amu.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.