Abstract

The objective of this study was to investigate differences in intima-media thickness (IMT) and diameter (D) measurements of the common carotid artery (CCA) in ultrasound imaging in normal subjects and renal failure disease (RFD) patients. Manual measurements by two experts and automated segmentation measurements (based on snakes and active contour models (ACM)) were carried out on 73 normal subjects, and 80 RFD patients. Statistical analysis was carried out using the Wilcoxon rank-sum test at p<0.05. Results demonstrated that the mean IMT and D measurements were significantly higher for the RFD group versus the normal group. Moreover, there was no significant difference between the manual and automated measurements. The ACM segmentation was slightly more accurate than segmentation based on snakes. Further work is needed to validate these findings on a larger group of subjects.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.