Abstract

Background: Autologous blood patch pleurodesis (ABPP) has been used in adults as an efficient and safe technique to address persistent air leak (PAL). A fibrin glue patch is also an alternative, but its elevated cost and technique can limit its routine use. Evidence of their use in the pediatric population, specifically in the neonatal age is scant. Case Presentation: We share our management experience in a series of 3 cases. The first 2 were treated exclusively with ABPP and showed clinical and radiographic improvement. The 3rd case, due to the persistence of the air leak, required extended thoracotomy and fibrin patch placement. Conclusion: The use of ABPP as an alternative for the treatment of neonates with PAL is a safe and efficient technique. The procedure is replicable and can be done at the bedside at a low cost. A fibrin glue patch should be considered as an alternative option when ABPP fails to resolve the leak.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.