Abstract

Bullets fired from civilian weapons are usually of low velocity, resulting in minimal tissue cavitation as compared to high-velocity weapons. A prospective protocol was initiated for patients sustaining a low-velocity gunshot to the extremity resulting in a stable, nonoperative fracture configuration. Treatment consisted of local irrigation and débridement, tetanus prophylaxis as required, a long acting cephalosporin intramuscularly, and splinting or casting of the fractured extremity. Twenty-five patients were managed by this protocol. This patient population was compared to a random retrospective sample of 25 patients with similar ballistic induced fractures and wounds managed by local débridement and 48 h of intravenous antibiotics. One infection occurred in each group, requiring further therapy. We conclude that the patient with a low-velocity gunshot induced fracture can be managed without the use of short-term intravenous antibiotics with no increased risk of infection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.