Abstract

Active surveillance is an established option for men with low risk prostate cancer. Multiparametric magnetic resonance imaging with magnetic resonance imaging-transrectal ultrasound fusion guided biopsy may better identify patients for active surveillance compared to systematic 12-core biopsy due to improved risk stratification. To our knowledge the performance of multiparametric magnetic resonance imaging in following men on active surveillance with visible lesions is unknown. We evaluated multiparametric magnetic resonance imaging and magnetic resonance imaging-transrectal ultrasound fusion guided biopsy to monitor men on active surveillance. This retrospective review included men from 2007 to 2015 with prostate cancer on active surveillance in whom magnetic resonance imaging visible lesions were monitored by multiparametric magnetic resonance imaging and fusion guided biopsy. Progression was defined by ISUP (International Society of Urological Pathology) grade group 1 to 2 and ISUP grade group 2 to 3. Significance was considered at p ≤0.05. A total of 166 patients on active surveillance with 2 or more fusion guided biopsies were included in analysis. Mean followup was 25.5 months. Of the patients 29.5% had pathological progression. Targeted biopsy alone identified 44.9% of patients who progressed compared to 30.6% identified by systematic 12-core biopsy alone (p = 0.03). Fusion guided biopsy detected 26% more cases of pathological progression on surveillance biopsy compared to systematic 12-core biopsy. Progression on multiparametric magnetic resonance imaging was the sole predictor of pathological progression at surveillance biopsy (p = 0.013). Multiparametric magnetic resonance imaging progression in the entire cohort had 81% negative predictive value, 35% positive predictive value, 77.6% sensitivity and 40.5% specificity in detecting pathological progression. Multiparametric magnetic resonance imaging progression predicts the risk of pathological progression. Patients with stable multiparametric magnetic resonance imaging findings have a low rate ofprogression. Incorporating fusion guided biopsy in active surveillance nearly doubled our detection of pathological progression compared to systematic 12-core biopsy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.