Abstract

A 32-year-old woman presented for evaluation of primary infertility. Because she had a history of iodine-induced hypothyroidism, conventional hysterosalpingography was contraindicated. Tubal patency was assessed by magnetic resonance imaging (MRI) after infusion of gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA). Visualization of the contrast medium in the peritoneal cavity revealed tubal patency. Our case indicates that MRI with gadolinium-diethylenetriamine pentaacetic acid is a safe, simple, and easy way to confirm that at least one tube is patent when a patient is at risk for hysterosalpingography. To our knowledge, this is the first report that tubal patency was diagnosed on MRI.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.