Residual stresses in ferromagnetic material affect the direction and structure of domains and generate the magnetic flux abnormality on the surface. Three-dimensional magnetic field on the surface of a circular-welding pipe specimen was inspected with 8mm lift-off before and after low-temperature annealing aimed for residual stress releasing. Small hole stress testing was also carried out with a contrast to the magnetic testing before annealing. The magnetic field characteristics and the residual stress distribution were compared and discussed. The normal component of magnetic field correlated with residual stress. The magnetic field abnormality on ferromagnetic material could be used for residual stress inspection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.