Abstract

The transport of vacuum arc plasmas through a 90/spl deg/ curved magnetic macroparticle filter was investigated using a high-current pulsed arc source with a carbon cathode. The peak arc current was in the kiloampere range, exceeding considerably the level of what has been reported in the literature. The main question investigated was whether magnetic macroparticle filters could be scaled up while maintaining the transport efficiency of small filters. In front of the cathode, we found that arc current dependent total ion saturation currents were in the range from 10% to 23% of the arc current. The best relative transmission was 25% (time integrated output/time integrated input) at a duct wall bias of 12.5 V and at an axial magnetic field of about 100 mT. The measured relative transmission of the used high-current arrangement is comparable to what has been observed with other low-current filters. The absolute measurable ion saturation currents at the filter exit reached 70 A at an arc current of about 1000 A.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.