Abstract
In this paper, lumen degradation is described by using a modified Brownian motion process for mid-power white-light LED packages, which were aged under step stress accelerated degradation test (SSADT). First, a SSADT model has been established based on the theory of equivalent accumulative damage. Then, a method was proposed to improve the accuracy of the parameter estimation by carefully modifying the estimator, which was proposed in the previous research. Experimental data show that parameters estimated by using SSADT model are very close to those estimated by using constant stress accelerated degradation test (CSADT) model, indicating the feasibility of the SSADT model. The experiment also indicates that SSADT can be used as an alternative to CSADT, as it enables comparable estimation accuracy, while using less testing time, a smaller sample size and less test capacity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.