The theory, design, implementation and experimental validation of a novel low-cost online diagnosis and location method for open-switch faults in voltage source inverters is presented. According to the analysis of the operating states in inverters, there are different collector-emitter voltages of the bottom power switches in faulty conditions compared with normal conditions. To reduce cost, the proposed method employs high-speed photocouplers to sense voltages of the bottom switches, and then a sample logic circuit is designed to implement the detection and location of the fault. The developed approach minimises the time interval between the fault occurrence and its diagnosis, and is validated by the experiment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.