Abstract
The energy consumption of a fermenter constitutes a major part of the operating expense of a single cell protein process. A low-pressure airlift fermenter was designed to reduce this cost. In this new design, the fermenter broth is kept below 120 cm in depth, and air alone is employed to fulfill the need of supplying oxygen, and cooling and agitating the broth. The use of low-pressure air from air blowers instead of air compressors lowers the capital cost of air delivery and reduces the energy consumption in the fermenter section to below 1 kWh/kg protein, a saving of over 70% as compared to a conventional stirred tank fermenter. It also eliminates the investment of mechanical agitators, heat exchangers, and air compressors. Sulfite oxidation studies confirmed the design concepts.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.