Abstract

Introduction and importanceWiring true lumen during Thoracic Endovascular Aortic Repair (TEVAR) is sometimes difficult in complicated Type B Aortic Dissection (TBAD).Case presentationWe treated a TBAD patient with large false lumen, compressed true lumen and multiple entries. After repeated wire misdirection to false lumen, we tried a new technique in which the wire in the false lumen was looped after entrance to true lumen and pushed distally. The looped wire was then used as guide to advance a second wire to the ascending aorta. TEVAR could then be completed with good result.DiscussionWiring the true lumen might be one of the most challenging steps during TEVAR in complicated TBAD. Several methods have been used to overcome the problems, but the cost and availability might be a problem in some countries. The looping wire technique may serve as an alternative method of guiding the process of wiring the true lumen during complicated TEVAR.ConclusionLooping wire technique can be used as an alternative method to facilitate true lumen wiring during TEVAR.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.